Wide-field hyperspectral camera

Plasmetrix Vitta

A C-mount hyperspectral camera for the optics you already own

Vitta adds a 400–700 nm spectrum to every pixel at a microscope port, a research ophthalmic port or the Vitta Stage, over one USB cable. The filter moves inside the camera body, so the camera and the sample stay still — no push-broom slit, no line stitching, and spatial detail set by your optics.

400–700 nm Linear variable filter C-mount USB 3.0 ENVI export
Vitta · C-mount
400–700 nm
Spectral range
6.41 MP
Full frame at every band
from 3 nm
Bandwidth (FWHM), by filter option
10–60 s
Full 400–700 nm cube, continuous scan
Applications

Where a full spectrum per pixel pays off

Slides on a microscope, leaves and seed on the Vitta Stage, and eye samples at a research port. Vitta suits samples that hold still.

H&E section rendered in true colour from a Vitta hyperspectral cube H&E · Vitta true colour
Cyto- and histopathology

See the stain, not just the colour

Fit Vitta to your microscope's C-mount port and add a 400–700 nm spectrum to every pixel of a slide. Record calibrated transmittance, compute optical density, compare stains and train tissue classifiers on spectra instead of RGB. Every band is a full-frame image, so spatial resolution stays with your objective. Move the filter aside and the same camera works as a monochrome microscope camera.

Published work with another hyperspectral microscope: on 65 H&E thyroid slides, sensitivity reached 91.5 % against 84.8 % on RGB, while accuracy differed by under 1 point.

Research use only. Not for use in diagnostic procedures.

Typical work

  • Plasmonic nanoprobes on cells: silver, gold–silver alloy, gold and nanoshell particles told apart by scattering spectrum, on a reflected-light or dark-field microscope
  • H&E tissue classification, bright-field, 480–630 nm window
  • Liquid-based cytology, bright-field

In development: chromogen unmixing and stain quality control.

Immunoplasmonic diagnostics →
Leaf rendered in true colour from a Vitta hyperspectral cube Leaf · Vitta true colour
Agro-environments

Pigment maps at leaf, seed and sediment scale

Place a leaf, a tray of seed or a filter on the Vitta Stage and map pigments across the visible range at up to 6.41 MP. Vitta records 400–700 nm at every pixel while the sample stays still under the stage's own LEDs. Follow chlorosis, lesions, colour change and ripening, or track chlorophyll and phycocyanin in algae and sediment. Export ENVI cubes to your own models.

For laboratory and growth-room use.

Typical work

  • Forestry and crop leaf pigments, with vegetation indices and per-leaf statistics in HyperAnalyser
  • Photosynthetic stress with PRI (531 and 570 nm), under controlled light
  • Foliar disease and lesions: visible symptoms
  • Grain and seed: chlorophyll loss near 680 nm

Range: the standard filter stops at 700 nm. NDVI and red-edge work needs the extended-range build described below; moisture and protein bands lie beyond 900 nm.

Retinal flat mount rendered in true colour from a Vitta hyperspectral cube Flat mount · Vitta true colour
Ophthalmic research

Spectral imaging for vision science

Map retinal and corneal tissue at full sensor resolution on the optics your lab already uses. Vitta records a 400–700 nm spectrum at every pixel of flat mounts, sections, ex vivo eyes, model eyes and phantoms. It connects through C-mount to a microscope port or to a research slit-lamp or fundus-camera port, and works as a standard monochrome camera with the filter moved aside.

Research use only. Not for diagnostic use or imaging of patients.

Typical work

  • Retinal flat mounts and sections on a microscope
  • Corneal sections and ex vivo cornea
  • Model eyes and phantoms at a fundus or slit-lamp port

Fit check first: we confirm the relay, beam, focus, illumination and wavelength calibration on your exact instrument. A global-shutter sensor option is recommended at ophthalmic ports.

Ask about camera, adapter and calibration →

Every target band of the three applications sits inside the Vitta range

Published target bands, on the specified 400–700 nm range.
Wavelength, nm400450500550600650700
Cyto- and histopathology
H&E stain window480–630 nm
Fluorophores, DAPI to AF647461–668 nm
Agro-environments
Leaf pigment effects467–589 nm
PRI band pair531–570 nm
Phycocyanin band depth600–640 nm
Chlorophyll loss in grain680 nm
Ophthalmic research
Macular pigment465 nm
Drusen autofluorescence510 nm

Extended range: if your application needs it, Vitta can be built to reach 850–900 nm with commercially available visible–near-infrared linear variable filters, such as those from Delta, which brings the red edge and the NDVI near-infrared band into reach.

Band positions come from published work and the Vitta specification. They show spectral coverage, not validated Vitta performance. Published sources: drusen, macular pigment, leaf pigments, PRI, phycocyanin, grain.

Configurations

Camera or complete imaging station

Fit Vitta to the optics you already have, or start with the Vitta Stage for macro samples with built-in illumination.

Plasmetrix Vitta hyperspectral camera with C-mount lens
CameraC-mount

Vitta Camera

The hyperspectral camera on its own, for a microscope camera port, a machine-vision lens, a research slit-lamp or fundus-camera port, or your own imaging rig. The filter scan happens inside the body, and a single USB cable carries both power and data.

Park the filter out of the beam and Vitta works as a standard monochrome camera. On a microscope, one camera covers routine and spectral imaging — no camera swap.

  • Sensor6.41 MP Sony STARVIS (BSI)
  • Optical mountStandard C-mount
  • Power & dataOne USB 3.0 cable, USB-C
  • Monochrome modeFilter parked out of the beam
  • Body157 × 63 × 31.5 mm
Custom sensor options on request
From US$9,900Request a quote →
Vitta Stage: hyperspectral camera on a rigid frame with two LED illuminators above a sample base
Complete systemMacro samples

Vitta Stage

A ready-to-use macro imaging station: the Vitta camera and lens on a rigid frame, two broadband LED illuminators on a constant-current driver, and a sample base that rises to bring flat or bulky samples into focus.

The LEDs are high-CRI types chosen for their extended spectral range, so the illumination covers the whole 400–700 nm band.

  • Illumination2 × high-CRI LED, constant current
  • Footprint179 × 179 mm
  • Camera to sample base≈ 180 mm
  • Sample base travel70 mm
  • Sample thickness1–50 mm
Broadband LED illumination included
Quote on requestRequest a quote →
OEM and integration Building Vitta into your own instrument? We quote it as a module, with your choice of sensor and filter. Talk to us →
Linear variable filter scan — leaf sample
Simulated scan of a leaf with a lesion, as recorded by Vitta
1 / 3

The whole field of view at every wavelength

Push-broom hyperspectral cameras see one line at a time and rebuild the image as the sample moves under a slit. Vitta records the full sensor frame at each filter position instead. Every frame is a sharp, complete image, so the spatial resolution is set by your lens or microscope objective and the sensor pixels.

Because each band carries the full 2D structure, frames can be aligned to each other to correct modest sample drift.

Full 2D frame per band No slit, no keystone Spectrum at every pixel Open ENVI cubes
Principle

How Vitta builds a hyperspectral cube

One motorized filter, a standard machine-vision sensor and calibrated software — no gratings, slits or external scan stages.

01

Filter scan

A linear variable bandpass filter travels across the sensor on an internal motorized stage, shifting the transmitted band step by step through the 400–700 nm range.

02

Wide-field frames

The camera records complete 2D frames at up to 58 fps as the filter travels. Wavelength shifts by about 36 nm across each frame, so every frame samples a slice of the spectrum across the field.

03

Cube reconstruction

Row-wise wavelength calibration assigns a wavelength to every pixel of every frame. The software resamples them into a regular (x, y, λ) cube.

04

Analysis & export

Convert to reflectance or transmittance against a reference, render true colour, map spectral classes — or export ENVI cubes to your own tools.

Advantages

What a wide-field, moving-filter design changes

The filter moves inside the camera instead of the sample moving under a slit. That one choice shapes everything below.

01

Wide-field 2D spectral acquisition

A complete 3088 × 2076 px image at every spectral step — no external push-broom stage and no slit losses.

02

Spatial detail preserved

No line-by-line reconstruction, spectral smile or keystone distortion. Resolution is set by your optics and the sensor, behind a high-throughput dielectric filter.

03

Full frames for drift correction

Every band contains the full 2D structure, so frames can be aligned to correct modest sample drift before the cube is assembled.

04

Quantitative spectra at every pixel

Contiguous spectra support calibrated reflectance and transmittance, spectral classification and training data for your own models. A stain-unmixing module is in development.

05

Targeted spectral windows

When an application needs only part of the range, the scan covers that window plus one sensor height. A 150 nm H&E window takes about half the time of a full cube, with a smaller data set.

06

One camera, two modes

Park the filter out of the beam and Vitta is a standard monochrome camera. On a microscope there is no camera swap between routine and spectral imaging, and one USB cable carries power and data.

Compared with other hyperspectral architectures

Push-broom (line-scanning) spectrographs

Limitation

They image a narrow slit while the slide or camera moves at a speed locked to the frame rate, so stage vibration and velocity jitter blur spatial detail.

Vitta

The filter moves inside the camera. Vitta sits on any stationary C-mount port and keeps the full 6.41 MP image at every step.

Electronically tunable filters (LCTF, AOTF)

Limitation

Polarizers and birefringent crystals lose 65–85 % of the light, and transmission falls below 10–15 % in the 400–480 nm band that matters for hematoxylin and Giemsa.

Vitta

A polarization-insensitive dielectric filter with 40–90 % peak transmission, rising from blue to red. Birefringent tissue such as collagen and muscle does not distort absorbance (OD) data when the sample is rotated.

Snapshot mosaic (Fabry–Pérot) cameras

Limitation

A 4 × 4 or 5 × 5 filter grid leaves only 4–6 % of the pixels for each band, and demosaicing adds fringes along sharp edges such as nuclear membranes.

Vitta

100 % native monochrome resolution at every wavelength, with no spatial interpolation. The standard filter gives about 20–30 independent bands and the narrow-band filter about 40–60.

Software

From raw scan to analysis

Two Plasmetrix applications cover acquisition and analysis, and the data stays in open formats.

Acquisition & reconstruction

HyperDevice

  • Camera and filter-scan control in one window, step or continuous
  • Region of interest and exposure settings
  • Row-wise wavelength calibration and reference normalization
  • Cube reconstruction by linear or cubic-spline resampling
  • Monochrome mode with the filter moved out of the beam
Cube analysis

HyperAnalyser

  • Spectra from any pixel or region
  • True-colour and single-band images
  • Spectral classes, PCA and spectral-angle maps
  • Visible vegetation indices and per-leaf statistics
  • Works directly on ENVI cubes
  • Stain-unmixing module in development
Open data ENVI (BSQ, BIL, BIP) 16-bit PNG or TIFF per band Cubes open directly in Python, MATLAB and other ENVI-compatible tools.
Specifications

Technical specifications

Standard configuration with a 6.41 MP back-illuminated Sony STARVIS sensor; its 2.40 µm pixels give Nyquist sampling for 10×–20× microscope objectives. The optical design accepts other machine-vision sensors, so custom sensor options are available on request.

Spectral
Spectral range400–700 nm (visible)
FilterLinear variable bandpass filter, moved inside the camera body
Bandwidth (FWHM)Two filter options: 3–9 nm (narrow-band) or 7–20 nm (standard)
Peak transmission25–80 % (narrow-band filter) · 40–90 % (standard filter)
Spectral samplingUser-set output step from 0.5 to 5 nm (60 to 300+ bands), full range or a targeted window
Independent bands≈ 40–60 (narrow-band filter) · ≈ 20–30 (standard filter)
Out-of-band blocking300–850 nm; fit a 720–750 nm short-pass filter for sunlight or halogen light
Sensor
SensorSony STARVIS (BSI)
Resolution3088 × 2076 px (6.41 MP)
Pixel pitch2.40 µm
Active area7.41 × 4.98 mm (1/1.8″)
Shutter & frame rateRolling shutter with global start · 58.6 fps
Bit depth8 / 10 / 12-bit (~71 dB); 16-bit by frame co-adding
Other sensorsCustom sensor options on request, including a 3.19 MP global-shutter sensor with 3.45 µm pixels
Scan
Filter driveInternal motorized stage
Scan modesStep-and-stare, or continuous at 1.0 mm/s (precision) to 5.0 mm/s (rapid)
Wavelength across one frame≈ 36 nm along the short sensor axis; a scan covers the window plus one sensor height
Full cube, 400–700 nmContinuous: 50–60 s at 1.0 mm/s · 10–12 s at 5.0 mm/s
Step-and-stare: ≈ 20 s at 100 ms exposure · ≈ 2.5 min at 2 s exposure
150 nm window (e.g. H&E, 480–630 nm)25–30 s at 1.0 mm/s · 5–6 s at 5.0 mm/s
Mechanical & software
Optical mountStandard C-mount — lenses and microscope camera ports
Power & dataSingle USB 3.0 cable (5 Gbit/s), USB-C connector
Monochrome modeFilter parked out of the beam — works as a standard monochrome camera
SoftwareHyperDevice (acquisition, reconstruction) · HyperAnalyser (analysis) · ENVI and 16-bit PNG or TIFF export
Vitta Stage
Footprint179 × 179 mm
IlluminationTwo high-CRI LED illuminators with extended spectral range, covering 400–700 nm
LED driverConstant-current
Sample space≈ 180 mm from camera to sample base; base rises 70 mm; samples 1–50 mm thick

Scan times are design values. For research use only; not for use in diagnostic procedures. Specifications subject to change.

Publications

Research using our hyperspectral camera

Peer-reviewed studies in which the Plasmetrix linear-variable-filter hyperspectral camera was used.

Biosensing Nanoprobes Dark-field

Methods and Instrumentation for Quantitative Analysis with Immunoplasmonic Nanoprobes

Elsevier Sensors & Actuators B · 2025
Bacteria detection Multispectral Nanoplasmonic

Dynamic Multispectral Detection of Bacteria with Nanoplasmonic Markers

RSC Nanoscale · 2023
Selected publications
Get started

Bring hyperspectral imaging to your bench

Tell us about your samples and optics — microscope port, macro lens, research ophthalmic port or the complete Vitta Stage — and we'll recommend the right sensor and configuration.

contact@plasmetrix.com  ·  Montreal, Quebec, Canada